REGENERATION SIZING / DIMENSIONS
Resistive Regeneration Sizing
Shunt regeneration is required to dissipate energy that is pumped
back into the DC bus during load deceleration. The amount of
shunt regeneration required is a function of the sum of
simultaneously decelerating loads. The loads need to be defined in
terms of system inertia, maximum speed, and deceleration
time. In addition, the duty cycle must be known. Contact Kollmorgen
Customer Support Network for application assistance at
SERVOSTAR 600
SERVOSTAR 600 DIMENSIONS
S603/06/10/14/20
Dimensions in mm (inches)
Model Watts Ohms Amplifiers A B C D E1 E2 F G
BAR-250 250 33 S603, S606, 330(12.99) 390(15.35) 412(16.22) 66(2.60) 44(1.73) 35(1.38) 4,5x9(.20x.35) 77(3.03)
BAR-500 500 33 S610, S614, S620 400(15.75) 426(16.77) 486(19.13) 92(3.62) 64(2.52) 64(2.52) 6,5x9(.20x.35) 120(4.72)
BAR-1500 1500 33 S606, S610, S614, S620 500(19.69) 526(20.71) 586(23.07) 185(7.28) 150(5.91) 150(5.91) 6,5x9(.20x.35) 120(4.72)