Model Output Continuous Output Peak Internal Power AC Input Rated Continuous Continuous
Current Per Phase Current Per Dissipation Line Input Internal External
(RMS/phase) Phase (Watts) Voltage Power (KVA) Regen Power Regen Power
(5 sec) (3 phase) @230 V (Watts) (Watts)
S603 3 6 40 230 1.4 80 500
S606 6 12 60 230 2.8 200 1,500
S610 10 20 90 230 4.6 200 1,500
S614 14 28 160 230 6.5 200 1,500
S620 20 40 200 230 9.3 200 1,500
Amplifier Ratings
AMPLIFIER SPECIFICATIONS
Power Regeneration Options
• Internal
• External - using BAR housed resistors
• Bus Sharing - Distributes regen power among
multiple amplifiers
Built in Parameter Unit
• Displays drive status information
• Parameters: Drive Address, baud rate, Velocity loop
tuning, Motor type, Position output information format,
brake, regen type
Motor Brake Control
• 24V optional holding brake in the motor can be
controlled directly by the SERVOSTAR 600
Power Inputs
• 230 VAC 3phase, 50 or 60 Hz, built in line filter for
CE requirements
• 24 VDC @ 1 amp (3 amps with brake) For Logic