CONFIGURABLE AND READABLE FUNCTIONS
Mode 0
The amplifier uses Input 1 only, depending
on the operation mode.
Mode 1
The amplifier uses Input 1 or 2, depending
on the operation mode.
Mode 2
Both inputs are switched off.
Mode 3
The amplifier uses Input 1, depending on
the operation mode. Input 2 is used for lim-
iting peak current.
Mode 4
The amplifier uses the sum of Inputs 1 and
2, depending on the setting of OPMODE.
Mode 5
The amplifier uses the product of Inputs 1
and 2, depending on the setting of
OPMODE. The voltage on Input 2 has the
effect of a weighting factor for Input 1.
OPMODE Input 1 Input 2
analog speed speed command inactive
analog torque torque command inactive
MOTIONLINK
• Change/Copy Motion Task
• Position Type (Rotary or Linear)
• Master/Slave
• Motion Task Stop
• In Position
• Set Position Registers
• Motion Task Start
• Acceleration ramp
• Deceleration Ramp
• Min Acceleration
• Max Velocity
• Position Capture (Positive or Negative Edge)
Motion Task (or Blocks)
OPMODE Input 1 + Input 2
analog speed speed setpoint
analog torque torque setpoint
OPMODE Input 1 Input 2
analog speed speed command inactive
analog torque inactive torque command
• Two Differential Analog Inputs that can be configured in the following ways:
Analog Input
OPMODE Input 1 Input 2
analog speed inactive inactive
analog torque inactive inactive
OPMODE Input 1 Input 2
analog speed speed command limits peak torque
analog torque torque command limits peak torque
OPMODE Input 1 • Input 2
analog speed speed setpoint
analog torque torque setpoint
Analog Output
• Two Analog Outputs can be configured for Actual Speed,
Actual Current, Commanded Speed, Commanded Current, or Contouring error window
• Signal dead band
• Signal offset
• Auto Offset command
• Input Configuration