KOLLMORGEN • Radford, Virginia • 1-800-77 SERVO
18
SYSTEM PERFORMANCE CURVES
Kollmorgen GOLDLINE XT and SERVOSTAR 600
1000
2000
500
1500
2500
0
TORQUE
SPEED (RPM)
Continuous
Duty Zone
Intermittent
Duty Zone
0
0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0
10.0 20.0 30.0 40.05.0 15.0 25.0 35.0
50.0 55.0
lb-ft
N-m
3.9 kW
(5.2 HP)
13
nn
Motor MT702A
nn
Amplifier: S620
Performance Specification Symbol Units Value
Cont. Torque at stall Tc lb-ft 16.5
N-m 22.3
Peak Torque at stall Tp lb-ft 35.6
N-m 48.3
Cont. Power
HP rated
HP 5.2
kW rated kWatts 3.9
Rated Speed Nr RPM 2200
Max. Speed Nmax RPM 2200
min J max J
Motor Inertia Jm lb-ft-s
2
0.00398 0.0096
kg-m
2
0.00540 0.0130
Motor Weight Wt lb 49.6 53.4
kg 22.5 24.2
1000
2000
500
1500
2500
0
TORQUE
SPEED (RPM)
Continuous
Duty Zone
Intermittent
Duty Zone
0
0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0
10.0 20.0 30.0 40.05.0 15.0 25.0 35.0
50.0 55.0
45.0
60.0
lb-ft
N-m
4.7 kW
(6.3 HP)
14
nn
Motor MT704A
nn
Amplifier: S620
Performance Specification Symbol Units Value
Cont. Torque at stall Tc lb-ft 23.1
N-m 31.4
Peak Torque at stall Tp lb-ft 41.2
N-m 55.9
Cont. Power
HP rated
HP 6.3
kW rated kWatts 4.7
Rated Speed Nr RPM 2000
Max. Speed Nmax RPM 2000
min J max J
Motor Inertia Jm lb-ft-s
2
0.0058 0.0140
kg-m
2
0.0078 0.0189
Motor Weight Wt lb 66.1 79.3
kg 30.0 36.0
500
1500
250
750
1250
1000
0
TORQUE
SPEED (RPM)
Continuous
Duty Zone
Intermittent
Duty Zone
0
0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0
20.0 40.0 60.010.0 30.0 50.0 70.0
lb-ft
N-m
5.8 kW
(7.8 HP)
15
nn
Motor MT706C
nn
Amplifier: S620
Performance Specification Symbol Units Value
Cont. Torque at stall Tc lb-ft 35.4
N-m 48.0
Peak Torque at stall Tp lb-ft 63.8
N-m 86.5
Cont. Power
HP rated
HP 7.8
kW rated kWatts 5.8
Rated Speed Nr RPM 1300
Max. Speed Nmax RPM 1300
min J max J
Motor Inertia Jm lb-ft-s
2
0.0093 0.0176
kg-m
2
0.0126 0.0239
Motor Weight Wt lb 79.3 92.5
kg 36.0 42.0
Notes:
1. Continuous duty operation is with motor mounted to aluminum faceplate of 400 in
2
, in 40° C ambient.
2. All curves shown at 60 Hz input, derate max. speed and peak power by 15% for 50 Hz operation.
3. All curves represent typical performance. Always allow appropriate safety factor when sizing systems.
Comentarios a estos manuales