DIMENSIONS/ORDERING INFORMATION
Resistive Regeneration Sizing
Shunt regeneration is required to dissipate energy that is pumped back
into the DC bus during load deceleration. The amount of shunt regener-
ation required is a function of the sum of simultaneously decelerating
loads. The loads need to be defined in terms of system inertia, maximum
speed, and deceleration time. In addition, the duty cycle must be known.
Application Note AS6000H details a calculation method to determine
proper regeneration sizing.
SERVOSTAR 600
SERVOSTAR 600 DIMENSIONS
S603/06/10
Dimensions in mm (inches)
F
A
B
C
E2
E1
D
G
Model Watts Ohms Amplifiers A B C D E1 E2 F G
BAR-250 250 33 S603, S606, S610 330(12.99) 390(15.35) 412(16.22) 66(2.60) 44(1.73) 35(1.38) 4,5x9(.20x.35) 77(3.03)
BAR-500 500 33 S603, S606, S610 400(15.75) 426(16.77) 486(19.13) 92(3.62) 64(2.52) 64(2.52) 6,5x9(.20x.35) 120(4.72)
BAR-1500 1500 33 S606, S610 500(19.69) 526(20.71) 586(23.07) 185(7.28) 150(5.91) 150(5.91) 6,5x9(.20x.35) 120(4.72)
325
(12.8)
275
(10.8)
"A"
265 (10.4)
with connector:
273 (10.7)
DIM. “A
3 AMP 70 (2.8)
6 AMP 70 (2.8)
10 AMP 70 (2.8)
14 AMP 100 (3.9)
20 AMP 120 (4.7)
KOLLMORGEN • Radford, Virginia • 1-800-77 SERVO
7