Vector SIMOVERT MASTERDRIVES 6SE70 VC Manual de usuario Pagina 51

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 57
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 50
Version 1.0 March 1, 2000 Page 51
A
D
C
B
Select Record Settings in
the Lower Left Corner
Select Desired Channels
to Record
Set the Record Interval
and Pre-trigger
Select Trigger Channel
To Trigger With a Binector, Select:
Trigger Channel = K431
Trigger Condition “=” “1 Hex”
K431 is the output of a Binector to
Connector Converter that will be
configured on the following page.
A
B
C
D
Each Interval = (4.0 / P340) seconds.
Pre-trigger is in Percentage (%).
Function
Diagram
[720]